Setting Paper Weight - Sekonic SR-3500 Operating Manual

Hide thumbs Also See for SR-3500:
Table of Contents

Advertisement

Data reading settings ■ Setting paper weight

■ Setting paper weight

Set detection sensitivity In the same paper weight as seat of use to detect double-feeding errors.
Paper weight can be set according to the following five types: "Automatic," "84g/m
2
2
m
," "128g/m
," and "157g/m
If it's set to "Automatic," the device detects double-feeding errors based on the weight of first
sheet read after the device is activated.
Also, in case it is set to "Automatic", if the count is set to "0", all the information of the paper
weight is cleared, and the device detects the double-feeding error based on the paper weight
after the device reads the first sheet.
1.
MENU
Press the
2.
UP
Use the
and
and press the
3.
UP
Use the
and
and press the
*
("
" mark flashes in the first column of the first line on the LCD.)
4.
UP
Use the
and
5.
FEED/ENTER
Press the
(The flashing "
6.
Keep pressing the
or press the
Note)
If it is set to "Automatic", paper weight is detected based on the weight
of the first reading sheet so that it is required to confirm if the double-
feeding error, etc., does not occur.
-44-
2
."
switch to enter the menu mode.
DOWN
switches to select the following parameters,
FEED/ENTER
switch.
DOWN
switches to select [Paper Weight] setting,
FEED/ENTER
switch.
DOWN
switches to set the value.
switch to save the setting value into memory.
*
" mark disappears from the LCD.)
CLEAR/EXIT
switch until it returns to normal mode,
MENU
switch to return to normal mode.
2
," "105g/
Paper weight
setting values
• Automatic
2
• 84g/m
2
• 105g/m
2
• 128g/m
2
• 157g/m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr-6500

Table of Contents