Electrolux ENV06 Service Manual page 39

Condenser dryer with heat pump
Hide thumbs Also See for ENV06:
Table of Contents

Advertisement

Power frequency not within limits
EH1
Voltage too high
EH2
Voltage too low
EH3
Voltage incongruent between boards
EC1
Frequency incongruent between boards
EC2
CRM resistor over time limit (only in diagnostics
EC3
mode)
Heat generator resistance relay (CRM)
EC4
CRM thermostat faulty
EC5
CRM piloting faulty
EC6
CRM pump TRIAC
EC7
CRM pump diode
EC8
CRM pump piloting faulty
EC9
Water canister empty
ECA
2008-03 ADL
Power supply problem (incorrect/interference);
Main circuit board faulty.
Power supply problem (incorrect/interference);
Main circuit board faulty.
Power supply problem (incorrect/interference);
Main circuit board faulty.
Power supply problem (incorrect/interference);
CRM board faulty
Power supply problem (incorrect/interference);
CRM board faulty.
CRM unit disconnected or faulty
CRM unit disconnected or faulty; relay on board
faulty
CRM unit disconnected or faulty
CRM board faulty
Pump wiring disconnected; pump faulty; TRIAC
faulty
Diode on wiring short-circuited
CRM board faulty
Canister level sensor wiring; canister level sensor
faulty; water tube obstructed.
38/58
Cycle stopped; if the correct power supply is
restored before the time-out has elapsed, the
Cycle stopped; if the correct power supply is
restored before the time-out has elapsed, the
599 70 66 79
cycle resumes
Cycle stopped
cycle resumes
OFF
OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading