Electrolux ENV06 Service Manual page 34

Condenser dryer with heat pump
Hide thumbs Also See for ENV06:
Table of Contents

Advertisement

Position of selector
8
9
10
2008-03 ADL
Components actioned
Conductimetric sensor. Duration of check 4
sec. during which the LED flashes.
If at the end of the test the result is correct,
the LED switches off; otherwise the LED
flashes continuously.
Float switch
Canister fill pump: with switch closed
Reading/Cancelling of the last alarm.
Turn the knob to position 10, taking care not
to pause on position 7, otherwise error E32
might occur
Operating
Door closed
Door closed
Max. time 30 sec.
33/58
Function checked
condition
Control of
conductimetric sensor
with the circuit open
Operation of float
(with sump empty)