11.3 Compressor for fan motor

The compressor cooling motor is located in the front
section, behind the right-hand section of the plinth.
Remove the two screws, move the cover slightly to
the left and remove the plinth.
Move the two motor retaining clips upwards and tilt
the motor slightly downwards.

11.4 Door lock

Remove the two screws, push the lock slightly
downwards and tilt forward to remove.

11.5 Door microswitch

Remove the screw, pull the microswitch slightly
outwards and to the left until it reaches the
connector.
Detach the connector and apply adhesive tape to
hold it in position on the front panel so that it is not
retracted inside the appliance.