Cabinet Dimensions; Required Clearances - KitchenAid KFRS271TSS Technical Education

Outdoor gas grill
Table of Contents

Advertisement

Cabinet Dimensions

Built-In Outdoor Grills
Enclosure and clearance dimensions that are
shown must be used. Given dimensions provide

required clearances.

The installation of this grill must conform with
local codes or, in the absence of local codes,
with either the National Fuel Gas Code, ANSI
Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2.
Copies of the standards listed may be
obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The grill drops into the opening and
is supported by its side flanges. Do not use a
bottom support.
3" (7.6 cm)
min to
open hood
12" (30.5 cm)
min to any
accessory
22�⁄� "
(58.1 cm)
C
35½"
(90.2 cm)
20 �⁄� "
(53.0 cm)
26" (66.0 cm) min
2½" (6.4 cm)
A
2¼"
(5.7 cm)
12" (30.5 cm)
min to any
accessory
7 �⁄� "
(18.7 cm)
10 ¾"
(27.3 cm)
Gas line
location at
1�⁄� "
rear of grill
(3.8 cm)
20 �⁄� "
(52.5 cm)
B
2 �⁄� "
(6.8 cm)
1�⁄� " (2.9 cm) min around
opening for mounting
optional doors or drawers
G
r
l l i
i S
e z
27" (68.6 cm)
36" (91.4 cm)
48" (121.9 cm)
Optional Access Doors*
27" (68.6 cm)
30" (76.2 cm)
36" (91.4 cm)
48" (121.9 cm)
Optional Drawers*
14" (35.6 cm)
Utility Drawers
14" (35.6 cm)
Trash Drawers
Built-in Outdoor Grill Enclosure Ventila-
tion for LP Gas:
An enclosure for an LP gas fuel tank is to be
ventilated by openings at both the top and lower
levels of the enclosure.
If converting to LP gas these vents are to
be in the enclosure:
An enclosure for use with an LP gas fuel tank
for built-in installation is to have at least one
ventilation opening on an exposed exterior side
located within 5" (12.7 cm) of the top is to be a
minimum of 20 in.² (129.0 cm²). One ventilation
opening within 1" (2.5 cm) of the bottom of the
enclosure and the bottom opening is to be a
minimum of 10 in.² (64.5 cm²). All vent openings
are to be unobstructed. Every opening is to be
a minimum of ⅛" (0.32 cm) wide.
20 in.
2
(129.0 cm
2
) min.
ventilation both sides
1" (2.5 cm) max.
10 in.
2
(64.5 cm
ventilation both sides
2-4
A
C
u
o t
t u
W
d i
h t
29
" (75.2 cm)
38 �⁄�" (98.0 cm)
50 �⁄�" (128.7 cm)
B
Cutout Width
25 �⁄� " (64.1 cm)
28 �⁄� " (71.1 cm)
34 �⁄� " (87.0 cm)
46 �⁄� " (117.4 cm)
C
Width
Depth
12¼" (31.8 cm)
23 �⁄�" (60.0 cm)
12¼" (31.8 cm)
23 �⁄�" (60.0 cm)
5" (12.7 cm) max.
2
) min.
5" (12.7 cm) max.

Advertisement

Table of Contents
loading

Table of Contents