Cabinet Cutout Dimensions - KitchenAid 740-0781 Installation Instructions And Use & Care Manual

Built-in
Table of Contents

Advertisement

Available languages

Available languages

The illustration below includes cutout dimensions and minimum spacing requirements. The illustration is for reference. The design of your cabinet
layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed.
Center or support surfaces must be level.
The installation of this grill must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The grill drops into the opening and is supported by its side flanges. Do not use a bottom support.
Built-in Outdoor Grill Enclosure Ventilation Requirements
Any enclosure is to be ventilated by openings at both the top and lower
levels of the enclosure. The following information is the minimum for
proper ventilation of your island construction.
There should be a minimum of 1 7/8" (4.4 cm) of clearance from the
bottom of the main burner bowl assembly and the front wall of the
island for proper ventilation.
NOTE: There should be no solid surface underneath the firebox
portion of the grill.
A minimum of 3" (7.6 cm) is required between the back of the grill
and any noncombustible materials. A minimum of
24" (61.0 cm) is required between the back of the grill and any
combustible material.

Cabinet Cutout Dimensions

The island must be vented in one of the 2 following ways:
A 90° or a 180° ventilation in the island to ensure that air flows
through the island at either 90° or 180°.
Any enclosure for built-in installation is to have at least one
ventilation opening on an exposed exterior side located within
2½" (6.0 cm) of the top and is to be a minimum of 20 in.
cm
2
). One ventilation opening within 1½" (3.0 cm) of the bottom of
the enclosure, and the bottom opening is to be a minimum of 10 in.
(64.5 cm
is to be a minimum of 1/8" (0.32 cm) wide.
2
). All vent openings are to be unobstructed. Every opening
2
(129.0
2
7