Cabinet Cutout Dimensions - KitchenAid 740-0781K Installation Instructions And Use & Care Manual

Built-in outdoor grill
Table of Contents

Advertisement

Available languages

Available languages

The illustration below includes cutout dimensions and minimum spacing requirements. The illustration is for reference. The design
of your cabinet layout can be personalized, but the dimensions for the cutouts and minimum spacing must be followed.
Center or support surfaces must be level.
The installation of this grill must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code,
ANSI Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The grill drops into the opening and is supported by its side flanges. Do not use a bottom support.
Built-in Outdoor Grill Enclosure Ventilation for LP Gas
Any enclosure is to be ventilated by openings at both the top
and lower levels of the enclosure. The following information is
the minimum for proper ventilation of your island construction.
There should be a minimum of 1 7/8" (4.4 cm) of clearance
from the bottom of the main burner bowl assembly island
for proper ventilation.
NOTE: There should be no solid surface underneath the
firebox portion of the grill.
A minimum of 3" (7.6 cm) is required between the back of
the grill and any noncombustible materials. A minimum of
36" (92 cm) is required between the back of the grill and
any combustible material.

Cabinet Cutout Dimensions

7
The island must be vented in one of the 2 following ways:
A 90º or a 180º ventilation in the island to ensure that air
flows through the island at either 90º or 180º .
Any enclosure for built-in installation is to have at least
one ventilation opening on an exposed exterior side
located within 2½" (6.0 cm) of the top and is to be a
2
minimum of 20 in.
(129.0 cm
within 1½" (3.0 cm) of the bottom of the enclosure, and the
bottom opening is to be a minimum of 10 in.
All vent openings a re to be unobstructed. Every opening
is to be a minimum of 1/8" (0.32 cm) wide.
2
). One ventilation opening
2
2
(64.5 cm
).

Advertisement

Table of Contents
loading

This manual is also suitable for:

750-0781k

Table of Contents