ALARM SETTING

ALARM item flow

MAIN MENU
LANGUAGE
SET
PRESET POSITION SET
CAMERA
SET
AUTO MODE
PAN
AUTO FLIP
ON
ALARM
OFF
FREEZE
OFF
REFRESH
OFF
STARTING POINT
OFF
MENU
END
A
Alarm input setting
External alarm switch
(alarm signal source)
1
2
3
4
5
6
7
8
(Selection screen)
ALARM
ALARM IN
1
MOVE MODE
OFF
ALARM OUT
1
ALARM
ALARM IN
PRESET
ALARM OUT
OFF
MENU
BACK
PRESET
MENU
(Setting screen)
ALARM IN 1
POLARITY
NO
MOVE
OFF
MOTION
OFF
ALARM OUT
OFF
ALARM IN 8
LINE OUT
OFF
DURATION
5S
POLARITY
MOVE
MOTION
PRESET
OFF
ALARM OUT
MENU
BACK
LINE OUT
DURATION
PRESET
MENU
B
Alarm output setting
(Selection screen)
ALARM
ALARM IN
1
MOVE MODE
OFF
ALARM OUT
1
(Setting screen)
ALARM OUT 1
POLARITY
NO
ALARM TIME
5S
Digital video recorder
(sold separately)
Preset Position
setting
PRESET N
1:0
11:X
2:0
12:X
3:0
13:X
4:0
14:X
5:0
15:X
6:0
16:X
7:0
17:X
8:0
18:X
9:X
19:X
10:X
20:X
8
Motion Sensor
1
setting
OFF
BACK
NO
OFF
OFF
OFF
OFF
C
5S
LINE OUT
OFF
Output of alarm
BACK
signal to system
controller
ALARM
ALARM IN
1
MOVE MODE
OFF
ALARM OUT
2
ALARM OUT 2
POLARITY
NO
ALARM TIME
5S
Buzzer or lamp
The following settings are necessary for alarm detection.
Connect the supplied alarm input expansion connector to the
alarm input connector, then connect the external alarm
(contactless) switch to the end of it.
In the menu for preset positions, select a preset position from 1
to 8. (Preset positions 9 and higher cannot be used for alarm
detection.)
By setting the MOTION SENSOR for the preset position (1 – 8),
external alarms and motion sensing can be detected at the
same time.
A ALARM IN (ALARM)
Make settings for time of alarm input. In the selection screen
ALARM IN field where "1" is shown, an alarm screen number up to
8 can be selected with the joystick lever (d or c). The ALARM IN
number of the selection screen is linked with the alarm switch
ON/OFF, the preset position (1 - 8) and the MOTION SENSOR.
MOVE MODE
With MOVE MODE, AUTO setting is only possible when MOVE is
set to ON for the corresponding ALARM IN setting screen.
For example, while the preset position is automatically being
switched, set ON for MOVE in the ALARM IN 1 setting screen. In
the next selection screen, select AUTO for MOVE MODE.
If an alarm is detected in this condition, the camera will move to
preset position 1 at the next automatic switch of preset positions,
and after pausing 5 seconds (DURATION initial setting), the
camera will return to the screen in use before the switch.
Note: Operations such as motion zoom will be suspended and
returned to AUTO MODE.
B ALARM OUT (ALARM)
Make settings for time of alarm output. In the selection screen
ALARM OUT field where "1" is shown, an alarm screen number up
to 2 can be selected with the joystick lever (d or c).
When ALARM OUT is set to OFF, alarms cannot be output to
peripheral equipment.
ALARM OUT
For example, when ALARM OUT is set to "1" in the ALARM IN 1
setting screen and ALARM OUT is set to "1" in the selection
screen, the alarm output image becomes the camera image taken
after moving to preset position 1. (If set to ALARM IN 3, image is
from preset position 3.)
By connecting the camera's alarm output connector (1 or 2) to the
input terminal of a time lapse video recorder or digital video
recorder, the preset position 1 image will be recorded. For alarm
output, be sure to match ALARM OUT number for each ALARM IN
setting screen with the ALARM OUT number in the selection
screen.
C LINE OUT
Sends the alarm signal to the system controller. When this signal is
received, the ALARM indicator lamp on the system controller will
flash. Alarm information such as date/time, camera and alarm type
will be displayed in the alarm list.