AUTO MODE SETTINGS
There are 3 types of automatic panning available in AUTO MODE: Sequential pan (SEQ), Tour mode (TOUR), and Auto pan (PAN).
AUTO MODE item flow
MAIN MENU
LANGUAGE
SET
‚
PRESET POSITION SET
‚
CAMERA
SET
‚
AUTO MODE
SEQ
‚
AUTO FLIP
OFF
ALARM
OFF
FREEZE
OFF
REFRESH
OFF
STARTING POINT
OFF
MENU
END
ENTER
English
A
SEQ; Sequential pan setting (See p36)
The SEQ function offers 2 types of sequential automatic display,
smallest to larger preset position number (STEP) or by a random
selection method unique to this device (RANDOM). It also allows
setting of pause times and pan times for each PRESET POSITION.
This function can be activated by pressing the SEQ and + buttons on
the CAMERA keypad of the system controller.
SEQUENCE
ORDER
STEP
PAUSE TIME
5S
[SEQ SPEED]
15
MENU
BACK
B
TOUR; Tour mode setting (See p36)
The TOUR function records an image track of all camera pan, tilt and
zoom operations done within a 30 second period and then allows
surveillance of this recorded image track. Two 30 second image tracks
can be recorded, TOUR 1 and TOUR 2. In addition, TOUR 1 and
TOUR 2 can be combined to create a separate 60 second image track.
When a W track is created, stored data for TOUR 1 and TOUR 2 is
cleared. To do this, set TOUR to "W".
The image track can be activated by pressing the TOUR and + buttons
on the CAMERA keypad of the system controller.
TOUR
TOUR
1
TRACE
OFF
‚
MENU
BACK
C
PAN; Auto pan setting (See p37)
The PAN function stores a start point and an end point and then pans
between them in a loop.
The following options are available for loop operation.
• Pause time can be set for the start/end points.
• Pan direction can be set to either right or left.
• Speed can be set for the pan motion (time of pan).
The loop can be activated by pressing the PAN and + buttons on the
CAMERA keypad of the system controller.
AUTO PAN
POSITION
START‚
PAUSE TIME
3S
DIRECTION
LEFT
[PAN SPEED]
15
MENU
BACK
– 35 –
Memory
TOUR1: 30 seconds
TOUR2: 30 seconds
W: 60 seconds (TOUR1+2)
CAM-1 FLOOR-2
CAM-1 FLOOR-2
CAM-1 FLOOR-2
CAM-1 FLOOR-3
CAM-1 FLOOR-3
CAM-1 FLOOR-3
CAM-1 FLOOR-4
CAM-1 FLOOR-4
CAM-1 FLOOR-4
TOUR1: 30 seconds
The start location
The end location