Airis Setting - Sanyo VCC-9300 Instruction Manual

Hide thumbs Also See for VCC-9300:
Table of Contents

Advertisement

CAMERA SETTINGS
IRIS setting
A
There are 2 possible settings for IRIS, autoiris (AUTO) and manual
iris (MANU).
Autoiris setting (AUTO)
Sets backlight compensation, magnification of electronic sensitivity
and iris level.
1
In the MAIN MENU, select SET for CAMERA and press the
ENTER button.
The CAMERA SETTING screen will appear.
ENTER
2
Use the joystick lever (j or l) to move the cursor to
VIEW SETTING, then press the ENTER button. (Ex: 1)
The VIEW SETTING 1 screen will appear and AUTO for IRIS
will be blinking.
ENTER
Available settings:
AUTO: Sets automatic adjustment of iris.
MANU: Sets manual adjustment of iris.
Note: When AUTO is selected, the following 3 types of detailed
backlight compensation settings will be available.
Multi-spot evaluative metering (MULT)
5 spot centerweighted average metering (CENT)
48 multi-spot metering (MASK)
3
Press the ENTER button.
The IRIS SETTING screen will appear.
CAMERA SETTING
SYNC
INT
PRIVACY MASK
SET
LENS
SET
VIEW SETTING
1
PRESET
OFF
MENU
END
VIEW SETTING 1
IRIS
AUTO ‚
WHITE BALANCE
ATW
SHUTTER
OFF
MOTION
OFF
APERTURE
ON
AGC
ON
GAMMA
ON
PRESET
OFF
MENU
BACK
– 22 –
Backlight compensation additional settings 1
Multi-spot evaluative metering (MULT)
1
Use the joystick lever (j or l) to move the cursor to
BLC, then use the joystick lever (d or c) to select a
backlight compensation method. (Ex: MULT) Then press
the ENTER button.
The BLC SETTING screen will appear.
ENTER
Available settings:
MULT (Multi-spot evaluative metering): Evaluates the entire
screen and corrects according to the best image obtained.
CENT (5 spot centerweighted average metering): Measures
light mainly at the center and corrects according to the best
image obtained. (See p23)
MASK (48 multi-spot metering): Covers bright areas such as
persons with mask patterns and treats light measurement
output as irrelevant. (See p24)
2
Use the joystick lever (d or c) to select the value of BLC
WEIGHT. (Sets backlight and brightness level.)
ENTER
Available settings: 0 – 15
Note: The larger the number, the more backlighting works.
3
Use the joystick lever (j or l) to move the cursor to
BRIGHT, and then use the joystick lever (d or c) to
select the compensation level.
Available settings: 0 – 15
Note: When the number becomes larger, it brightens, and the
compensation level can be set for the brightness of the
backlighting.
4
Canceling a settings screen
Use the joystick lever (l) to select BACK for MENU, then
press the ENTER button. The VIEW SETTING screen will
reappear.
To return to the normal screen, use the joystick lever (l
c) to select END for MENU, then press the ENTER button.
Note: When using multi-spot evaluative metering, the background
behind the target object will become very dark. If a target
image in the center of the image is too bright while using the
multi-spot evaluative metering mode, switch to the 5 spot
centerweighted average metering mode.
IRIS SETTING
BLC
MULT ‚
SENSE UP
OFF
(LEVEL)
40
PRESET
OFF
MENU
BACK
BLC SETTING
(BLC WEIGHT)
7
(BRIGHT)
7
PRESET
OFF
MENU
BACK
English

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vcc-9300p

Table of Contents