S6
seconds 2–65*
S7
seconds 1–255*
S8
seconds 0–65
S10
100 ms
S11
1 ms
S28
decimal
S30
1 minute 0–255
S35
decimal
S36
decimal
MT5634ZPW-PCI
3 AT Commands, S-Registers and Result Codes
Range
Default
2*
50*
2
1–254
20
50–150* 95*
0, 1–255 1
0
0–1
0
{0,2}, {1,3} N/A
{4,6}, {5,7}
Description
Sets the time the modem will wait
after it goes off-hook before it be-
gins to dial the telephone number.
Sets the time the modem will wait
for a carrier signal before aborting
a call. Also sets the wait for si-
lence time for the @ dial modifier.
Sets the length of a pause caused
by a comma character in a dialing
command.
Sets how long a carrier signal
must be lost before the modem
disconnects.
Sets spacing and duration of dial-
ing tones.
0 disables, 1–255 enables V.34
modulation.
S30 specifies the length of time (in
minutes) that the modem waits
before disconnecting when no
data is sent or received. This
function is only applicable to
buffer mode. (Also see \T com-
mand.)
0 disables, 1 enables the V.25 data
calling tone, which allows remote
data/fax/voice discrimination.
This register specifies the action
to take in the event of negotiation
failure when error control is se-
lected. (See S48.)