MessageSaver User Guide
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
Command:
Values:
Default:
Description:
38
\A n
Select Maximum MNP Block Size
n = 0, 1, 2, or 3
3
\A0
64-character maximum.
\A1
128-character maximum.
\A2
192-character maximum.
\A3
256-character maximum.
\B n
Transmit Break
n = 0–9 in 100 ms units
3
In non-error-correction mode only, sends a break signal of the
specified length to a remote modem. Works in conjunction
with the \K command.
\G n
Modem Port Flow Control
n = 0
0
\G0
Returns an OK for backward compatibility with some soft-
ware.
\G1
Not supported—responds ERROR.
\J n
Data Buffer Control
n = 0
0
\J0
Enable data buffer—serial port speed is independent of con-
nect speed.
\J1
Disable data buffer—serial port speed is forced to the line
speed.
\K n
Break Control
n = 0–5
5
Controls the response of the modem to a break received from
the computer, the remote modem, or the \B commnd. The re-
sponse is different for each of three different states.
Data mode. The modem receives the break from the computer:
\K0
Enter online command mode, no break sent to the remote mo-
dem.
\K1
Clear data buffers and send break to the remote modem.
\K2
Same as \K0.
\K3
Send break immediately to the remote modem .
\K4
Same as \K0.
\K5
Send break to the remote modem in sequence with the trans-
mitted data.
Data mode. The modem receives the break from the remote
modem:
\K0
Clear data buffers and send break to the computer.
\K1
Same as \K0.
\K2
Send break immediately to the computer.
\K3
Same as \K2.