&F n Load Factory Settings
n = 0
None
&F0
Load factory settings as active configuration.
&G n V.22bis Guard Tone Control
n = 0, 1, or 2
0
&G0 Disable guard tone.
&G1 Set guard tone to 550 Hz.
&G2 Set guard tone to 1800 Hz.
&J n
Auxiliary Relay Control
n = 0
0
&J0
The auxiliary relay is never closed.
&J1
Not supported—responds ERROR.
&K n Flow Control Selection
n = 0, 3, or 4
3
&K0 Disable flow control.
&K3 Enable CTS/RTS hardware flow control.
&K4 Enable XON/XOFF software flow control.
&M n Communications Mode
n = 0
0
&M0 Asynchronous mode.
&M1 Not supported—responds ERROR.
&Q n Asynchronous Communications Mode
n = 0, 5, 6, 8, or 9
5
&Q0 Asynchronous with data buffering. Same as \N0.
&Q5 Error control with data buffering. Same as \N3.
&Q6 Asynchronous with data buffering. Same as \N0.
&Q8 MNP error control mode. If MNP error control is not estab-
lished, the modem falls back according to the setting in S36.
&Q9 V.42 or MNP error control mode. If neither error control is es-
tablished, the modem falls back according to the setting in S36.
&S n Data Set Ready (DSR) Control
n = 0 or 1
0
&S0
Force DSR always high (on).
&S1
Let DSR go high only during a connection.