Delayed Violation #2 & #3 - Aeris Manta Operating Manual

Table of Contents

Advertisement

DELAYED VIOLATIO #2 (Fig. 84)
The anta cannot calculate Decompression times for Stop
Depths much greater than 60 FT (18 ) and offers no indica-
tion of how much time spent underwater would result in the
need for a greater Stop Depth.
If the Decompression obligation requires a Deco Stop Depth
between 60 FT (18 ) and 70 FT (21 ), the NIBG will flash
and the graphic message DECO > STOP > 60F (18 ) will
scroll at the top of the display.
When this occurs, you must make a controlled Ascent to just
deeper than, and stay as close as possible to, 60 FT (18 )
without causing the NIBG to flash.
When the Required Stop Depth indicates 50 FT/ 15 , etc.,
you can ascend to those Stop Depths and continue decom-
pressing.
DELAYED VIOLATIO #3 (Fig. 85)
If you descend deeper than the OD ( aximum Operating
Depth) of 330 FT (100 ), the UP Arrow will flash, and the
Current Depth and ax Depth displays will only indicate 3
dashes ( - - - ) signifying that you are Out of Range.
The graphic message TOO > DEEP will scroll at the top of the
display until Ascent is made above 330 FT (100 ).
88