 Pressing/releasing the S button momentarily (< 2 seconds) will toggle the Set
Point between OFF and ON.
 Pressing/releasing the A button momentarily (< 2 sec) will accept the setting
and access the SET FREE DEPTH ALAR 1 screen.
 Depressing the button for 2 seconds, or if no button is pressed during a
period of 2 minutes, the display will revert to the FREE SURF AIN screen.

FREE DEPTH ALARMS (FDA)

The anta features 3 FREE DEPTH Alarms that can be Set at progressively deeper
Depths and turned OFF/ON.
> If Alarm 1 is set OFF, then Alarms 2 and 3 will be disabled.
> If Alarm 2 is set OFF, Alarm 3 will be disabled.
When each of the Depths are reached during a dive, 3 short beeps will sound 3
times and the message DPTH will be displayed 3 times.
 Pressing/releasing the A button momentarily (< 2 seconds) while the SET FREE
EDT ALAR screen is displayed will access SET FREE DEPTH ALAR 1 with
the Set Point flashing.

Sequence of FREE ode Alarm Setting Access:

FREE SURF AIN  depress A and S 2 seconds >>
SET FREE EDT AL  press A less than 2 seconds >>
SET FREE DEPTH AL 1  press A less than 2 seconds >>
SET FREE DEPTH AL 2  press A less than 2 seconds >>
SET FREE DEPTH AL 3  press A less than 2 seconds >>
FREE SURF AIN