48
Pressing and releasing the S button (< 2 seconds) will
toggle between ON and OFF.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
DEPTH ALAR screen with the Set Point flashing.
Pressing and releasing the A button momentarily and
repeatedly (< 2 seconds each time) will step through the
other SET A screens.
Depressing the A and S buttons simultaneously for 2
seconds will save the setting and revert back to the SET A
screen.
Depressing and holding the button for 2 seconds or if
no button is pressed for a period of 2 minutes operation
will revert to the NOR or GAUG SURF AIN screen.
SET ORM/GAUG DEPTH ALARM, information includes
(Fig. 42):
> Graphic DPTH
> Depth Set Point value flashing, with AX and FT (or )
icons.
Pressing and releasing the S button momentarily (< 2
seconds) will step through the Set Points from 30 to 330 FT
(10 to 100 ) in 10 FT (1 ) increments at a rate of 1 Set
Point per press of the button.
Depressing and holding the S button will scroll through the
Set Points at a rate of 4 Set Points per second until it is
released.