Gaug.dive.main; Adjust.brightness; Gaug.dive.alt; Delayed.violation - Aeris A300 CS Operating Manual

Dive computer
Table of Contents

Advertisement

GAUG DIVE MAIN, information includes (Fig. 67A/B):
Either Elapsed Dive Time (EDT) or a Run Time can displayed on the Main screen with the other on the ALT (Alternate) screen.
> BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level).
> Current Depth with FT (or M) icon.
> Graphic EDT with Elapsed Dive Time (up to 9:59 hr:min) , or graphic RUN TIME with Time (up to 9:59 min:sec, then 0:10 to
9:59 hr:min), 0:00 until started and after reset.
> Graphic TMT 1 (2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG when
no Transmitter is in use (SPG = Submersible Pressure Gauge).
> Air Time Remaining (min) with icon, up to 99 (remains at 99 when greater), blank if SPG.
> VARI (AR) - while ascending.
• A (2 sec) - to access Adjust Brightness.
• A (< 2 sec) - to access ALT.
• M (2 sec) - to access the TMT Switch Menu*.
• M (< 2 sec) - to interchange EDT and Run Time.
• S (< 2 sec) - to start/stop Run Timer, only while it is on the Main. This operation is blocked when the screen is dimmed due
to Auto Dim and when pressed to acknowledge Alarms when they strike.
• S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
• S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
• S (2 sec) - to access Compass*.
ADJUST BRIGHTNESS, information includes (Fig. 68):
> xx % (last value saved). Up to 60% max when Low Battery Warning or Alarm.
• S (2 sec) - to step back to the Main without changing the value.
• A (< 2 sec) - to step upward through values of 10% to 100% one at a time in increments of 10%.
• M (< 2 sec) - to step down through values one at a time.
• S (< 2 sec) - to save the % setting and revert to the Main.
• Revert to Main in 10 sec, if no button is pressed.
GAUG DIVE ALT, information includes (Fig. 69A/B):
> RUN TIME = min:sec (hr:min), or EDT = hr:min.
> MAX D = xxx FT (or xx.x M).
> TIME = hr:min with AM (or PM) if 12 Hour Format.
> TEMP = xx F (or C).
• A (< 2 sec) - to access revert to Main.
• M (< 2 sec) - to step back to Main.
• Revert to Main in 10 sec, if no button is pressed.
GAUG DELAYED VIOLATION 3 (DV3)
Upon descent deeper than the 330 FT (100 M)*, the Audible will sound for 10 seconds.
*Beyond this depth, the A300 CS cannot accurately perform calculations and display data.
Upon ascending above 330 FT (100 M), Current Depth will be restored, however, Max Depth will display 3 dashes for the
remainder of that dive. Also, the Log for that dive will display 3 dashes as the Max Depth.
DV3 MAIN, information includes (Fig. 71) -
> BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level).
> Current Depth as dashes ( - - - ) with FT (or M) icon.
> Graphics GO UP TOO DEEP with Up Arrows (red), flashing.
> Graphic TMT 1 (or 2, 3, 4), one in use.
> Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG.
> Air Time Remaining (min) with icon, blank if SPG.
> VARI (AR) - while ascending.
• A (2 sec) - to access Adjust Brightness.
• A (< 2 sec) - to access ALT.
• M (2 sec) - to access the TMT Switch Menu*.
• S (< 2 sec) - to restore screen Brightness from the Auto Dim level to the % level you last adjusted it to.
• S (< 2 sec) - to acknowledge alarms; this will also restore screen Brightness if it was dimmed by Auto Dim.
• S (2 sec) - to access Compass*.
© 2002 Design, 2014
*These items can only be accessed while viewing the Main.
*These items can only be accessed while viewing the Main.
37
A300 CS OPERATING MANUAL
76
BATT
FT
F
0:14
EDT
TMT 1
ATR
1350
23
PSI
Fig. 67A - GAUG DIVE MAIN
(EDT selected)
68
BATT
FT
F
1:06
RUN
TIME
TMT 2
ATR
2480
19
PSI
Fig. 67B - GAUG DIVE MAIN
(Run Timer selected)
ADJUST BRIGHTNESS
1 0 0 %
Fig. 68 - BRIGHTNESS
RUN T I M E =
1 : 0 6
MAX D =
1 2 8 F T
T I M E =
9 :5 2 A M
TE M P =
7 3 F
Fig. 69A - GAUG DIVE ALT
(EDT is on Main)
EDT =
0 :1 4
MAX D =
1 2 8 F T
T I M E =
9 : 5 2 A M
T EM P =
7 3 F
Fig. 69B - GAUG DIVE ALT
(Run Timer is on Main)
- - -
BATT
FT
G O U P
TO O D E E P
TMT 3
ATR
1040
PSI
Fig. 71 - GAUG DV3 MAIN
Doc. No. 12-7287-r03 (7/14/14)
AR
AR
AR
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents