Handling Of The Parameters Of The System Bus - BONFIGLIOLI actice Instruction Manual

Table of Contents

Advertisement

4.13
As soon as the system bus expansion module EM-SYS exists in a frequency inverter,
the actual value parameters for system state and bus state are activated and can be
monitored in the actual value menu VAL of the control unit KP500 or with the VPlus
PC program in the menu Actual values \ Systembus.
Note:
All the setting parameters for the configuration of the system bus are not directly ac-
cessible for the user. For defined customer applications, pre-defined XPI files can be
generated by VECTRON for the VPlus PC program, with which the necessary parame-
ters are visible for the user. The application-relevant variables are then available in
these XPI files.
Note:
The method of working via an XPI file has its reasoning in the fact that deep interven-
tions in the system are possible via the system bus and can lead to serious problems
in the application with an untrained user. Via the XPI files, a user is given a selection
list pre-defined by VECTRON.
Attention! The configuration of the necessary parameters for the system bus are
Experienced users have complete access to all the existing sources and possible input
links with the XPI file of the active functions. The selection depends on the selected
configuration and control procedure.
The display of the parameters when using the XPI file is according to the following
structure:
System bus
42
42

Handling of the parameters of the system bus

The actual value parameters are on control level 3 and are thus available
for the user at any time.
XPI files can be read in addition to the loaded parameter information of
the frequency inverter into the VPlus PC program.
In the menu of the software under the point Edit you find the command
"Read in XPI file".
accessible by a XPI file with the help of the VPlus PC program.
The control unit KP500 does not support this functionality.
If the expansion module system bus EM-SYS is installed additionally to a
communication module for the field bus connection (CM-232, CM-485 or
CM-PDP) in the frequency inverter, the parameterization can be made
with the interface adapter KP232.
Basic Settings
Master Functions
SYNC-Identifier
SDO1-Identifier
SDO2 Set Active
PDO-Identifier
900Node-ID
903Baud-Rate
904Boot-Up Delay
919SYNC-Time
918SYNC-Identifier
921RxSDO1-Identifier
922TxSDO1-Identifier
923SDO2 Set Active
924RxPDO1-Identifier
925TxPDO1-Identifier
926RxPDO2-Identifier
927TxPDO2-Identifier
928RxPDO3-Identifier
929TxPDO3-Identifier
06/05