Division Marks; Level - BONFIGLIOLI actice Instruction Manual

Table of Contents

Advertisement

assignment of the inputs:
(1): X410A.1
(2): X410A.2
(3): X410A.3
(4): X410A.4
5.1.2
The number of increments of the connected speed sensor can be parameterized via
the parameter
the speed sensor is to be selected according to the speed range of the application.
The maximum number of division marks S
300 kHz of the speed sensor inputs EM-ENC (track A) and EM-ENC (track B).
S
To ensure a good true running of the drive mechanism, a sensor signal must be
evaluated at least every 2 ms (signal frequency f = 500 Hz). The minimum number of
division marks S
can be calculated from this requirement. The evaluation of four signal edges per mark
is firmly defined in the function of speed sensor 2.
S
494 Division marks speed sensor 2
5.1.3
Via the parameter
selected:
0 -
2 -
50
50
Terminal
Speed sensor input EM-ENC track A+
Speed sensor input EM-ENC track A-
Speed sensor input EM-ENC track B+
Speed sensor input EM-ENC track B-

Division marks

Division marks speed sensor 2
60
s/min
=
300
000
Hz
max
n
of the incremental speed sensor for a required minimum speed n
min
60
s/min
=
500
Hz
min
A
n
min
Parameter
No.
Description

Level

Operation mode Level
Operation mode
push-pull
unipolar
Socket X410A
X410A
X410B
2
4
3
1
494. The number of division marks of
is defined by the limit frequency of f
max
n
= Max. speed of the motor in RPM
max
max
n
=
min
A
=
495, the following operation modes can be
Push-pull signals (5 V) are evaluated
(according to specification RS-422A/RS-485).
Unipolar signals (10 V...24 V) at A+ and B+ are evalu-
ated.
input
Min. speed of the motor in RPM
4 (quadruple evaluation)
Setting
Min.
Max.
1
8192
Function
=
max
min
Fact. Sett.
1024
06/05
06/05