Power Via 13.5V - AMX MXT-2001-PAN Installation & Hardware Reference Manual

Modero x series g5 touch panels
Hide thumbs Also See for MXT-2001-PAN:
Table of Contents

Advertisement

NOTE: Refer to the Power via 13.5V section on page 41 for details on wiring a power connection.
8.
Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify that the
panel is receiving power and functioning properly to prevent repetition of the installation.
NOTE: Do not disconnect the connectors from the touch panel. The unit must be installed with the attached connectors before
being inserted into the drywall.
NOTE: Conf igurations that use the limited access USB port on the side of the connector box may require a right angle mating
connector (not included) for connection to the device.
9.
Insert the four temporary mounting posts of the panel into the openings on the Backbox and slide the panel onto the Backbox
(FIG. 32). This will temporarily hold the panel during the rest of the installation.
Note that FIG. 32 shows the MXD-1901-PAN, but the illustration applies equally to the MXD-2001-PAN. Also note that FIG. 32
shows a landscape panel but the installation of a portrait panel is essentially the same, other than the vertical orientation.
4X Mounting posts
Note:
Additional detailed installation and product drawings are available to view/download at www.amx.com
MXD-1901-PAN installation (Landscape)
FIG. 32
NOTE: When installing the panel, do NOT press on or near the center of the panel. Too much stress at the center may damage
the touch screen surface. When installing the panel, pressure should be applied toward the ends of the panel ONLY.
10. Use the six provided screws, three at each end, to secure the touch panel to the Backbox.
Use only the provided screws, as other screws may damage the touch panel.
11. Snap the decorative side covers onto each end of the panel.
12. Reconnect the terminal Ethernet and USB cables to their respective ports.

Power via 13.5V

The MXT-2001-PAN and MXT-1901-PAN use a 13.5V
captive wire PWR connector. The incoming PWR and GND wires from the power supply must be connected to the corresponding
locations within the PWR connector.
NOTE: Connecting power to the panel should be done using the included 2-pin 3.5mm captive wire connector included with the
device. This connector is retained within its port with locking screws instead of the pins on each side of standard captive wire
connectors, and using force to insert a standard captive wire connector may damage the device.
Modero X® Series G5 Touch Panels - Installation & Hardware Reference Manual
Side cover
4X Mounting post openings
6X 4-40 X 1/4" LONG FLAT HEAD
TORQUE TO 5±.2 IN LBS
-compliant power supply to provide power to the panel via the 2-pin 3.5mm
Installing Wall-Mount (MXD) Panels
Side cover
41