Installing Wall-Mount (MXD) Panels

A Note About Wall and Rack Installation

Some products are installed in areas of differing temperature and cooling methodologies. These include products installed in walls,
racks, cabinets, etc. Those areas may have different temperatures and/or cooling approaches that must be taken into consideration
to maintain the product within the specified operating temperature.
FIG. 20 shows an AMX device installed in a wall with a filled volume (such as with insulation or concrete), as well as with a closed
volume (such as between studs in an otherwise finished wall). The diagram shows how heat generated by the device or other
devices may have no way to escape, and may build up to levels that may affect device operation.
Heat convection in filled or closed volume, limited or no convection
FIG. 20
In FIG. 21, the diagram displays an AMX device in a typical rack mounting, with full air circulation around the front and back of the
device. In this case, the main concern is with heat building up between components, possibly to levels that may affect device
operation.
RACK MOUNTED DEVICES
Heat convection in rack-mounted devices
FIG. 21
Modero X® Series G5 Touch Panels - Installation & Hardware Reference Manual
T2
T1
T3
T1
AMX DEVICE
T4
Installing Wall-Mount (MXD) Panels
FILLED OR CLOSED
VOLUME, LIMITED OR
NO CONVECTION
T1, T2 < TOpMax
T1, T2 > TOpMin
T2
T1, T2, T3, T4 < TOpMax
T1, T2, T3, T4 > TOpMin