Power Via Poe; Ethernet Cable Installation And Modification - AMX MXT-2001-PAN Installation & Hardware Reference Manual

Modero x series g5 touch panels
Hide thumbs Also See for MXT-2001-PAN:
Table of Contents

Advertisement

Mounting Surface
Installing the MXD-1001 / MXD-701
FIG. 45
NOTE: If a gap is observed between the panel and the Backbox, or feel any binding while locking down the panel, stop
immediately and verify that no cables or other items are in the way. Do not force the panel into position, as this can cause
damage to the touch screen or the panel electronics.
10. Reconnect the terminal Ethernet and USB cables to their respective ports.

Power via PoE

Power for the MXD-1001 and MXD-701 is supplied via PoE (Power Over Ethernet ), utilizing an AMX-certified, capacitive touch-
compliant PoE injector such as the PS-POE-AT High Power PoE Injector (FG423-81) or other approved AMX PoE power source.
The incoming Ethernet cable should be connected to the RJ45 port on the cable attached to the device.
Ethernet Cable Installation and Modif ication
In tabletop installations where concealing the Ethernet cable is desired, a hole at least 1.00" (2.54 cm) in diameter is required in
the surface to allow passage of the female RJ45 connector (FIG. 46). If using a smaller hole is unavoidable, you will need to
disconnect the Ethernet cable (ECA5968-05) from the device, to feed the male end of the cable through.
Bottom of the MXT-701/1001
FIG. 46
NOTE: The minimum diameter hole through which the Ethernet cable may pass is 0.50" (1.27 cm).
To disconnect and reconnect the Ethernet cable on the MXT-701 and MXT-1001to allow use of a hole smaller than 1.00" in
diameter:
1.
On a soft surface, turn the MXT-1001 face-down to access the bottom of the device.
2.
Remove the clamp holding the Ethernet cable (FIG. 46).
3.
Remove the Ethernet cable connector and pull the cable out of the clamp.
4.
Pass the Ethernet cable (ECA5968-05) through the hole, with the RJ45 connector on the other side of the installation surface
from the device.
5.
Press the Ethernet cable back into the clamp.
Do NOT tighten the clamp at this time.
Modero X® Series G5 Touch Panels - Installation & Hardware Reference Manual
Backbox
Ethernet Cable
Clamp
Connector
Latch Hooks
Snaps
Installing Wall-Mount (MXD) Panels
50