Wall
4X Installation Clamp
for Wall Thickness
.37 [12.01] to .98 [25.0]
MXD-1901-PAN Backbox installation (Landscape)
FIG. 30
4.
Remove any knockouts as needed on either long dimension of the Backbox to facilitate incoming wiring and pull the wiring
through the resultant holes.
5.
Push the Backbox into the wall opening. Insure that the locking tabs lie flush against the Backbox, and that the Backbox goes
freely into the opening.
6.
Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug.
NOTE: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM]. Applying
excessive torque while tightening the tab screws, such as with powered screwdrivers, can strip out the locking tabs or damage
the plastic Backbox.
Not all of the tabs must be extended to lock the Backbox in place, but extending a minimum of the top and bottom tabs is

highly recommended.
Apply enough pressure to the screw head to keep the box flush with the wall: this ensures that the locking tabs will tighten

up against the inside of the wall.
The Backbox is clear to allow visual confirmation that the tabs have been extended and are gripping the wall, as well as in

assisting with removal if necessary.
For additional strength, #4 mounting screws (not included) may be secured through circular holes located at the left and

right sides of the MXD-2001-PAN (see FIG. 30). In order to prevent damage to the touch panel, make sure that these are
flush with the Backbox.
7.
Insert each connector into its corresponding location along the back of the device (FIG. 31).
Ethernet 10/100 Port
MXD-2001-PAN / MXD-1901-PAN - rear connectors
FIG. 31
Modero X® Series G5 Touch Panels - Installation & Hardware Reference Manual
Note:
Additional detailed installation and product drawings are available to view/download at www.amx.com
8X Knock Outs
Remove For Cable
Routing As Needed
13.5V
Power Port
Installing Wall-Mount (MXD) Panels
Cables Routed to
Wall Opening
Mounting screws
placement (optional)
Type A USB Port
(limited access)
40