Spectrophotometer Unit Calibration White Tile Error; Spectrophotometer Unit Eject Guide Not Mounted; Spectrophotometer Unit Backing Plate Error; Spectrophotometer Sensor Cover Open - Canon iPF6400S Basic Manual

Hide thumbs Also See for iPF6400S:
Table of Contents

Advertisement

iPF6400S Basic Guide

Spectrophotometer Unit Calibration white tile error.

Cause
The White Calibration Tile is not
installed.
The White Calibration Tile is dirty.
The performance of part of the
Spectrophotometer Sensor may
be impaired.

Spectrophotometer Unit eject guide not mounted.

The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.
There is a foreign object on the Spectrophotometer Eject
Guide.
The performance of part of the Spectrophotometer Unit
may be impaired.

Spectrophotometer Unit Backing plate error.

Cause
The White/Black Backing Plate is not installed
correctly.
The White/Black Backing Plate is soiled.

Spectrophotometer Sensor Cover open.

The Spectrophotometer Sensor Cover of the
Spectrophotometer Unit is open.

Spectrophotometer Unit cover open.

The Spectrophotometer Unit Cover of the
Spectrophotometer Unit is open.
152
Install the White Calibration Tile.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")➔User's Guide
Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")➔P.56
If this message is still displayed after cleaning the White Calibration Tile, we
recommend adjusting the Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")➔User's Guide
Cause
Remove and correctly attach the White/Black Backing Plate, and then
press the OK button.
(See "Switching the White/Black Backing Plate (Optional) Color.")➔
User's Guide
Clean the White/Black Backing Plate and then press the OK button.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")➔P.56
Cause
Cause
Corrective Action
Corrective Action
Make sure that the Spectrophotometer Eject Guide is
loaded in the correct position, push it in all the way, and
press the OK button.
Remove the foreign object and press the OK button.
Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your
Canon dealer for assistance.
Corrective Action
Corrective Action
Close the Spectrophotometer Sensor Cover and press the
OK button.
Corrective Action
Close the Spectrophotometer Unit Cover and press the OK
button.