Adjusting The Set Room Temperature For The Displayed Heating Circuit; Selecting The Operating Program For The Displayed Heating Circuit - Viessmann VITOTROL 300 RF Operating Instructions Manual

Wireless remote control for one, two or three heating circuits
Table of Contents

Advertisement

About the controls
Standard menu
A
Wednesday 25.05.2011 13:42
B
14°
D
Heating circuit 1
A Header
The following current data is
shown:
■ Operating program
■ Day of the week with date
■ Time
■ Transmission and reception qual-
ity of the wireless connection
■ Battery condition
B Current outside temperature
C Current room temperature (actual
room temperature)
Adjusting the set room temperature for the displayed heating
circuit
Press the following buttons:
+/–
for the required value.
"OK" to confirm.

Selecting the operating program for the displayed heating circuit

1. Press the following buttons:
or
or
operating program is active.
12
(cont.)
20.5°
Menu
depending on which
C
D Information bar
The following functions are shown if
they are active:
■ "Screed drying"
■ "External hook-up"
■ "External program"
■ "Holiday program"
■ If the Vitotrol 300 RF is not in its
table-top dock or wall mounting
bracket:
– "Mobile test location"
– "Weak batt charge"
– "Poor wireless conn."
2. Select the required operating pro-
gram:
"Heating and DHW"
or
"Only DHW"
or
"Standby mode"
(Frost protection monitoring for
the boiler and DHW cylinder is
active)