  • Page 1 VIESMANN Installation and service instructions for contractors Vitotrol 200 RF Wireless remote control for one heating circuit For applicability, see the last page VITOTROL 200 RF Please keep safe. 5602 119 GB 7/2017...
  • Page 2 Hot surfaces can cause burns. Replace faulty components only with genuine ■ Before maintenance and service work, switch Viessmann spare parts. OFF the appliance and let it cool down. Never touch hot surfaces on the boiler, burner, ■ flue system or pipework.
  • Page 3: Safety Instructions

    For replacements, use only original spare parts supplied or approved by Viessmann. Safety instructions for operating the system If you smell gas Condensate Danger...
  • Page 4 Index Index 1. Safety and liability Operational reliability ................Liability ....................2. Information Symbols ....................Intended use ..................Product information ................3. Preparing for installation Installation location ................Operation with or without room temperature hook-up ......■ Wireless connection ................■...
  • Page 5: Operational Reliability

    Safety and liability Operational reliability Danger Only operate wireless components indoors. ■ Wireless signals can interfere with electronic ■ Avoid impairment through moisture or dust. devices, particularly cardiac pacemakers, hear- ■ Ensure the wireless components do not come into ing aids and defibrillators. contact with gases, vapours or solvents and prevent If any such equipment is fitted, users should long-lasting direct insolation.
  • Page 6: Intended Use

    One heating circuit can be operated with a The Vitotrol 200-RF can be connected to the relevant Vitotrol 200 RF. For each of the max. 3 heating circuits Vitotronic control unit with the associated wireless within a heating system one Vitotrol 200 RF can be base station.
  • Page 7: Installation Location

    The wireless components operate with a frequency of 868 MHz. Select the installation site of the Vitotrol 200 RF so that the radio signals are transmitted as vertically as possi- ble through walls and floors to the wireless base sta- tion or Vitotronic 200.
  • Page 8 Installation sequence Overview of the installation and commissioning process Steps Page Position the Vitotrol 200-RF close to the wireless base station or the Vitotronic with integral — wireless interface. Commissioning the Vitotrol 200-RF: With Vitotronic with wireless base station ■ With Vitotronic with integral wireless interface ■...
  • Page 9: Fitting The Wall Mounting Base

    (see page 10 or 11). Fig. 2 Inserting the batteries Note As soon as power is first supplied to the Vitotrol 200 RF, the commissioning assistant starts automatically. The display shows "C1" and "Lrn" flashes. Fig. 4 Fig. 3...
  • Page 10 The initialisation takes approx. 5 min. The default display appears. Fig. 5 4. Press OK on the Vitotrol 200 RF. The Vitotrol 200 RF transmits a signal to log on to the wireless base station. Successful connection to the wireless base sta- ■...
  • Page 11 "H 2" for heating circuit 2 04. Press OK on the Vitotrol 200 RF. "H 3" for heating circuit 3 The Vitotrol 200 RF transmits a signal to log on to the wireless base station. 11. OK to confirm. Successful connection to the wireless base sta- ■...
  • Page 12 Vitotrol 200 RF Fig. 7 "d3" Transmission path between Vitotrol 200 RF and wireless base station Vitotrol 200 RF and Vitotronic control unit with integral wireless interface "d4" Transmission path between the wireless out- side temperature sensor and wireless base...
  • Page 13: Changing The Display Contrast

    Commissioning Checking the reception quality at the… (cont.) Meaning of display Display Value in dBm Reception quality 0 to Very good – 79 to Good – – 84 to Adequate – – 88 to Inadequate – – 92 to No reception –...
  • Page 14 Troubleshooting Fault display symbol flashes on the display if a fault has occurred. For troubleshooting, see the installation and service instructions for the relevant Vitotronic control unit or for the heat generator with Vitotronic with integral wireless interface If the display shows , the wireless connec- tion has been interrupted or has not been established yet.
  • Page 15: Ordering Parts

    Parts lists Ordering parts The following details are required when ordering parts: ■ Serial no. (see type plate ■ Position number of the part (from this parts list)
  • Page 16 Parts lists Parts list 0002 0001 0003 0004 Fig. 8...
  • Page 17: Parts List

    Parts lists Parts list (cont.) Pos. Part 0001 Wall mounting base 0002 Programming unit 0003 Installation and service instructions 0004 Operating instructions...
  • Page 18 Specification Specification Power supply 2 LR 6/AA/Mignon batteries , 2600 mAh – Battery life Approx. 2 years Radio frequency 868 MHz Protection class IP rating IP 30 Permissible ambient temperature Operation 0 to +40 °C ■ Storage and transport 20 to +65 °C ■...
  • Page 19: Declaration Of Conformity

    Certificates Declaration of conformity Vitotrol 200-RF We, Viessmann Werke GmbH & Co. KG, D-35107 Allendorf, declare as sole responsible body that the named product complies with the provisions of the following directives and regulations: 2014/53/EU 2011/65/EU RoHS II Applied standards:...
  • Page 20 Wireless base station..........10 Wireless connection............. 7 Wireless interface............8 KM BUS..............10 Applicability Serial No.: 7441652 Viessmann Werke GmbH & Co. KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com...