Blackmagicdesign Blackmagic URSA Installation And Operation Manual page 52

Table of Contents

Advertisement

Mounting Batteries
53
Batt
2
Batt
4
GND
6
Monitor 1
8
GND
10
+12V Out
12
The rear view of the adapter's connector housing. Refer to the
wire configuration table for a description of each pin.
This enables battery power to your camera. You can also connect additional wires for features such as
12 V output and battery status. Refer to your battery plate information, plus the diagram and tables
on this page for help connecting the wires. If you require further assistance visit the Blackmagic
Design support center at www.blackmagicdesign.com/support.
Wire Configuration Table
1
Batt
Pins
Signal
3
Batt
1,2,3,4
Batt
5
GND
5,6,9,10
GND
7
Monitor0
7
Monitor0
9
GND
11 EnableN
8
Monitor1
12
+12 V out
11
EnableN
Each Batt and GND pin supports 3 amps. Make sure all Batt and GND pins are connected. To monitor
the battery status using Anton Bauer, IDX, or Blueshape plates, follow the connection table below:
Anton Bauer
IDX
Blueshape
Secure any unused wires by cutting them as close as possible to the rear of the adapter connector.
Color
Direction
Red
To URSA
Black
Blue
To URSA
Green
To URSA
Orange
From URSA
White
To URSA
Connect the blue/white striped wire to the housing blue wire at pin 7.
Connect the green wire to the housing green wire at pin 8, and the grey wire to
the housing blue wire at pin 7.
Connect the blue wire labelled "SMBC " to the housing green wire at pin 8.
Connect the brown wire labelled "SMBD" to the housing blue wire at pin 7.
Description
12 V to 20 V
Analog battery level or open drain data
line (20 V max)
Open drain clock line (3.4 V max)
12 V regulated output 1.5 A max (18 W)
Connect to GND to enable +12 V out.
Leave floating if +12 V out is not required.