Brother DCP-7080 Service Manual page 85

Hide thumbs Also See for DCP-7080:
Table of Contents

Advertisement

 Error code 9701
Size Error DX
Press Stop Key. Specify the correct paper and load the same size paper as the
Printer driver setting.
A tray set to duplex printing-incompatible size was specified in duplex printing.
<User Check>
• Specify A4 or Letter size paper in the driver and set paper with the same size to the
specified paper tray.
Step
Main PCB failure
1
 Error code A000
Scan Unable
Remove the original document. Turn the power off, then on again.
Image processing cannot be completed correctly because the number of pixels required for
image processing is insufficient in the scanned data for the second side of the document.
Step
Incorrect correction data for
1
second side CIS unit
Second side CIS unit failure
2
Main PCB failure
3
 Error code A200
Document Jam
Clear the scanner jam, then press the Stop Key.
The first side document scanning position sensor detected that the document length was 90
cm or longer while scanning the document.
<User Check>
• Set A4 or Letter size paper.
• Remove the jammed document.
Step
First side document scanning
1
position actuator caught in some
sections of the machine
First side document scanning
2
position sensor failure
Main PCB failure
3
Cause
Replace the main PCB ASSY.
Cause
Execute "Set CIS scan area
55)".
Replace the second side CIS unit.
Replace the main PCB ASSY.
Cause
Reattach the first side document scanning
position actuator.
Replace the first side document scanning
position sensor PCB ASSY.
Replace the main PCB ASSY.
2-50
Remedy
Remedy
(function code:
Remedy
Confidential