4) Attach the double-sided tape to the FFC holder ASSY as shown in the figure below.
(If the old double-sided tape remains attached, replace it with new tape.)
FFC holder ASSY
5) Fold the second side CIS flat cable at 2012 mm away from the second side CIS unit
side.
Mountain fold
Valley fold
Reinforcing tape
6) As shown in the illustration below, pass the second side CIS flat cable through the FFC
holder ASSY while fitting the mountain-folded section to the rib on the FFC holder ASSY.
Then secure the second side CIS flat cable with the double-sided tape attached to the
FFC holder ASSY.
Pass through here.
FFC holder ASSY
Fig. 3-43
2012 mm
Second side CIS flat cable
Fig. 3-44
Second side CIS flat cable
Double-sided tape
Fig. 3-45
3-52
Double-sided tape
FFC holder ASSY
Rib (fit mountain-folded
section to rib)
CIS side
Electrode
Confidential