Checking/Regulating The Air Pressure; Emptying/Cleaning The Water Bowl Of The Air Fi Lter/Regulator - Pfaff 5489 Instruction Manual

Table of Contents

Advertisement

10

Checking/regulating the air pressure

.04
Fig. 10 - 04
10
Emptying/cleaning the water bowl of the air fi lter/regulator
.05
Fig. 10 - 05
1
2
1
Care and maintenance
● Check the air pressure on gauge 1 every
time before operation.
2
● Gauge 1 must show a pressure of 6 bar.
● Regulate this pressure if required.
● To do so, pull knob 2 up and turn it accor-
dingly.
Emptying the water bowl
● Water bowl 1 empties itself automatically
when the air hose is disconnected from
the air fi lter/regulator.
Cleaning the fi lter
● Unscrew water bowl 1 and take out fi l-
ter 2.
● Clean the fi lter with compressed air
or with isopropyl-alcohol, part number
95-665735-91.
● Screw in fi lter 2 and screw on water
bowl 1.
Switch off the machine.
Disconnect the air hose at the
air fi lter/regulating unit.