AC Power Adapter Specifications

This section describes the specifications for the AC power adapter supplied with
GX Series gateways.
AC Power Adapter Input
The input voltage range is 90 VAC to 264 VAC.
Input Voltage
Input Frequency
The maximum input current is 500 mA at 100–240 VAC.
The inrush current will not exceed 70 A at 100–240 VAC input and maximum load
from a cold start at 25°C.
AC Power Adapter Output
Minimum
Output Voltage
11.4 VDC
AC Power Adapter Environmental Specifications
Operating
Operating Temperature
Relative Humidity
Altitude
Vibration
Non-operating
Storage Temperature
Relative Humidity
Vibration and Shock
AC Power Adapter Reliability and Quality Control
When the power supply is operating within the limits of this specification, the
MTBF of the AC power adapter is at least 50,000 hours at 25°C (MIL-HDBK-
217F).
AirLink GX Series Specifications
Minimum
90 VAC
100–240 VAC
47 Hz
50/60 Hz
Typical
Maximum
12.0 VDC
12.6 VDC
°
0
C ~ 40°C (operates normally)
10% ~ 90%
Up to 2,000 meters
1.0 mm, 10–55 Hz, 15 minutes per cycle for each axis (X, Y, Z)
°
-30
C ~ 70°C
10% ~ 90%
MIL-STD-810D, method 514
Typical
Maximum
264 VAC
63 Hz
Test conditions
0 ~ 1.5 A loading