AirLink GX Series Hardware User Guide
60
Gateway Management
•
AirLink Management Service cloud-based gateway management application
For more information, go to www.sierrawireless.com/ALMS.
•
ACEManager web-based gateway configuration software
For more information, refer to the ALEOS Software Configuration User Guide.
•
AT Commands
For more information, refer to the ALEOS Software Configuration User Guide.
ALEOS Application Framework
•
Lua language coding platform
•
Remote application management
•
Eclipse-based IDE
•
Integrated real-time debugging
Input/Output
•
Configurable I/O on power connector
•
Input ON voltage: 3.3 VDC to 30 VDC
•
Input OFF voltage: 0 VDC to 1.2 VDC
•
Output maximum switching capability 200 mA @ 30 VDC
Power Consumption
Table 4-13: GX Series gateway power consumption (without X-Card)
AirLink GX Series Gateways (no X-Card installed)
Maximum current draw at 12 V
Typical current draw at 12 V
Low Power Mode current draw at 12 V
Additional Power Consumption with X-Cards Installed
Table 4-14
outlines the increase in power consumption if you have an X-Card
installed in the GX Series gateway.
Table 4-14: Additional power consumption with X-Card installed
Dual Ethernet
Change Typical
148 mA
Change Maximum
200 mA
a. Values are averaged over 2 minutes at +12 V at room temperature.
1 A
0.45 A
50 mA
Wi-Fi X-Card
X-Card
110 mA
155 mA
a
Serial I/O X-Card
19 mA
30 mA