60

Gateway Management

AirLink Management Service cloud-based gateway management application
For more information, go to www.sierrawireless.com/ALMS.
ACEManager web-based gateway configuration software
For more information, refer to the ALEOS Software Configuration User Guide.
AT Commands
For more information, refer to the ALEOS Software Configuration User Guide.
ALEOS Application Framework
Lua language coding platform
Remote application management
Eclipse-based IDE
Integrated real-time debugging
Input/Output
Configurable I/O on power connector
Input ON voltage: 3.3 VDC to 30 VDC
Input OFF voltage: 0 VDC to 1.2 VDC
Output maximum switching capability 200 mA @ 30 VDC

Power Consumption

Table 4-13: GX Series gateway power consumption (without X-Card)
AirLink GX Series Gateways (no X-Card installed)
Maximum current draw at 12 V
Typical current draw at 12 V
Low Power Mode current draw at 12 V
Additional Power Consumption with X-Cards Installed
Table 4-14
outlines the increase in power consumption if you have an X-Card
installed in the GX Series gateway.
Table 4-14: Additional power consumption with X-Card installed
Dual Ethernet
Change Typical
148 mA
Change Maximum
200 mA
a. Values are averaged over 2 minutes at +12 V at room temperature.
1 A
0.45 A
50 mA
Wi-Fi X-Card
X-Card
110 mA
155 mA
a
Serial I/O X-Card
19 mA
30 mA