Environmental Specifications - Sierra Wireless AirLink GX Series Hardware User's Manual

Hide thumbs Also See for AirLink GX Series:
Table of Contents

Advertisement

Rev 8 Nov.15

Environmental Specifications

Operating temperature: -30°C to +70°C (-22°F to +158°F)
Storage temperature: -40°C to +85°C (-40°F to +185°F)
Humidity: Maximum 90% RH @ 60°C (140°F)
Table 4-15: Environmental Test Specifications
Category
Operational /
Non-operational
Temperature
Operational
Non-operational
Humidity
Operational
Drop
Non-operational
Vibration
Operational
Shock
Operational
Thermal Shock
IP Rating
Wi-Fi X-Card
IEEE 802.11b/g/n
Both access point and client capability
When used as an access point, up to 8 clients can connect simultaneously
When used as a client, can connect to one of up to 10 configured access
points.
Security:
· WEP 64-bit and 128-bit encryption with H/W TKIP processing
· WPA/WPA2 (Wi-Fi Protected Access)
· AES-CCMP hardware implementation as part of 802.11i security
SMA antenna connector
Frequency range: 2.4 GHz
Number of channels:
802.11b:
· USA, Canada, and Taiwan—11
· Most European countries—13
· France—4
· Japan—14
1. The AC adapter has a narrower range of operating temperatures. See AC Adapter
AC Power Adapter Environmental Specifications
2. UL Listed for use in ambient temperatures not exceeding 60
AirLink GX Series Specifications
Reference
MIL-STD-810G, 501.5, 502.5
MIL-STD-810G, 501.5, 502.5
MIL-STD-810G, 507.5
ISTA 2A 2001, test categories 1, 4, 5, and 6
or equivalent
MIL-STD-810G, test method 514.6, 527
MIL-STD-810G, test method 516.6
MIL-STD-810G, test method 503.5
IP64
on page 65.
1 2