INSTALLERS INFORMATION - LOCATION

Issue 3
The following pages contain information relating to Installation and Service.
Installation and Service must be carried out by an authorised person only.
When positioning the heater, the main points to consider are:
1. Flue connection and terminal to comply with AS/NZS 5601. Only Rinnai flueing compo-
nents to be used.
2. Warm air distribution.
3. Ensuring that the area in which the appliance is installed has adequate fixed ventilation,
this fixed ventilation must be provided as per AS/NZS 5601.
4. The heater must not be installed where curtains or other combustible materials could
come into contact with it. In some cases, curtains may need restraining. See below for
minimum clearances required.
5. This heater is not designed to be inbuilt.
6. Electrical requirements
The heater has a power cord with a three pin plug
supplied. The power cord passes through the rear
right hand side of the heater front assembly. Rinnai
recommends the heater be plugged into a 240V, 10A
earthed power point. The power point must be a
minimum of 300 mm to the side of the heater (it must
not be above the heater). Alternatively - unit can be
direct wired if the power supply is to be concealed.
Consult a qualified electrician if direct wiring is
required as it must comply with AS/NZS 5601 and
AS3000.
Royale - Freestanding ETR
- 13 -
Issue 3 - ©Rinnai