Disassembly Procedures
!
Drain Pump Removal
1. Disconnect power supply to unit.
2. Gain access to bottom of unit.
3. Remove 4 screws securing panel to the bottom of the
cabinet.
4. Remove drain hose and tub hose from pump.
5. Disconnect electrical connector .
©2004 Maytag Services
WARNING
16023430 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
6. Remove 4 screws and slide pump mounting bracket
to free tabs and remove motor.
.
17