Disassembly Procedures
!
Drain Pump Removal
1. Disconnect power supply to unit.
2. Remove Back Cover.
3. Remove clamp and Drain Hose.
4. Remove clamp and Pump Hose.
©2005 Maytag Services
WARNING
16025909 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
5. Remove wiring connector.
6. Remove three 13mm bolts securing Drain Pump to
base.
7. Remove screw securing Drain Pump to bracket.
Twist Drain Pump clockwise to remove.