Disassembly Procedures
!
9. Remove nut, washer, and isolator from below and lift
out strut.
NOTE: When replacing the strut, replace them one at a
time, making sure the nut below the base is
tightened for the proper compression of the strut
isolator. This should be done prior to placing the
strut rod into the socket on the tub.
Drain Pump/ Pressure Switch Removal
1. Disconnect power supply to unit.
2. Lift Top Cover.
3. Remove Front Panel.
4. Disconnect hose at tub drain.
5. Disconnect outlet hose at pump.
6. Disconnect wiring harness plugs.
7. Turn Drain Pump counterclockwise approximately
45°.
44
WARNING
16022808 Rev. 0
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
8. Lift Drain Pump away from washer base and remove.
©2003 Maytag Appliances Company