MAINTENANCE

A qualified service person recommended by your YUNCA dealer should conduct an annual
inspection and undertake any maintenance required on your EROS. Its venting and installation
must be checked to keep it running safely and efficiently. The following procedures should be
performed only by a qualified service person. The gas supply and electrical power should be
isolated whenever any maintenance procedures are undertaken.
Note: the door can only be removed after the heater has been turned off for long enough so that
the door has cooled to touching temperature.
Removing The Front Door
1. First the top panel must be removed, to do this grip panel at the front edge and the back
corner. Pulling up will disengage the locating pin. Then work the hand position around the
panel to disengage all the locating pins.
Care needs to be taken not to damage any panels by keeping the panels from touching each
other during this process
2. The side panels must be removed, to do this grip the top of the and pull out to disengage the
locating pins. The panel should be swung out to about 20 degrees and then pulled up to
release the locating pins at the bottom. Take care to ensure the door is not damaged by the
side removal.
3. This will expose the restraining latches at each side. To open these latches lift the butterfly
grip forward and twist it through 180 degrees.
4. The front door can now be removed by griping it by its back bottom corners by lifting it
away from the heater.
Removing The Glass For Replacement.
1. Remove the front door as described above, and place front down on a soft surface.
2. Remove the bottom front glass retainer by taking out the four screws along the base of the
door.
3. To remove the front glass place one hand under it and lift it up and out of the doorframe.
4. New glass with gasket attached can be ordered through your YUNCA EROS agent.
Note: Only recommended heat resistant glass may be fitted.
5. Place replacement glass in position in the reverse order of removal.
6. Replace bottom glass retainers with their respective bolts and screws.
Note: Tighten the screws and bolts alternately, do not over tighten, to avoid damaging glass.
25-07-01