APPENDIX A:

GAS TYPE CONVERSION

If at any stage the heater is required to run on a gas other than that which it was factory equipped
a conversion kit can be ordered through your YUNCA dealer.
The conversion should be done by a suitably qualified person.
Step 1. Isolate the heater from the gas supply
2. Remove the front door as previously described.
3. Remove the inner hearth by removing the screws along the lower front and lifting clear.
4. Remove logset.
5. Disconnect the burners from their supply pipes.
6. Unscrew the brass injector holders from the burner frame.
7. The brass injectors are threaded into the end of the injector holders, they can be
removed with a 7mm spanner, and the new injectors fitted.
8. An approved sealing compound should also be used.
9. The burner module can be unscrewed, it is held in place by two screws located between
the burners.
8.
The pilot assembly must be removed from the burner module. To do this, undo the
screw on the left hand end of the burner support bracket and slide the pilot assembly
down. The two screws that attach the pilot assembly are now accessible under the front
burner, remove these screws.
25-07-01
Page 19 of 23
Operation Instructions for Eros Free Standing Gas Fire July 2001.doc