LEEDZ FUZZY LOGIC control FREESTANDING GAS HEATER FEBRUARY 2010 INSTALLATION, OPERATION, MAINTENANCE & WARRANTY INFORMATION These instructions should be stored in a convenient safe place for ready reference. Page 1 of 19 Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010...
GAS CONTROL VALVE CONNECTIONS FAN REMOVAL TROUBLE SHOOTING GUIDE 15 - 16 Appendix A PARTS LIST Appendix B INJECTOR SIZES Appendix C WARRANTY Appendix D WIRING DIAGRAM Appendix E WARRANTY REGISTRATION Page 2 of 19 Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010...
(without the fan boost). Ref page 12. The installation of the YUNCA LEEDZ (Fuzzy Logic control) FLUED GAS HEATER must be carried out by a suitably qualified person and comply with the current New Zealand installation code, NZS 5261:2003.
The earthquake brackets are located at the back corners of the heater. The Yunca Leedz does not require a floor protector (hearth), and if desired can be placed directly on to carpet or wood flooring.
CLEARANCES and DIMENSIONS The YUNCA LEEDZ (Fuzzy Logic control) FLUED GAS HEATER should be installed with clearances equal to or greater than those recommended below (Fig 3) and comply with NZS 5261/ AG601. This is to ensure adequate air circulation around the heater and avoid heat damage to wall coverings.
CONNECTING THE HEATER TO A GAS SUPPLY Burn only the fuel for which the heater is equipped. The YUNCA LEEDZ (Fuzzy Logic control) is shipped from the factory equipped to burn either Natural Gas or L.P.G. N.B. The Yunca LEEDZ (Fuzzy Logic control) Heater cannot be converted from LPG to NG, or vice versa.
LEEDZ INFRA-RED REMOTE CONTROL with AUTO TIMER. N.B.- DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE! Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010 Page 8 of 19...
Page 9
LEEDZ INFRA-RED REMOTE CONTROL with AUTO TIMER. POWER ON/OFF: First check that two fresh AAA batteries are inserted. If the remote appears faulty, please try replacing the batteries. At first the remote may appear to be on, but it is likely that is not so.
Page 10
You are effectively temporarily overriding the automatic control, e.g. if you wish to stop the fire running at an earlier time. Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010 Page 10 of 19...
The AUTO light will flash (when the fire is off) as a reminder that the timer has been activated. MAINTENANCE A qualified service person should conduct an annual inspection and undertake any maintenance required on your LEEDZ (Fuzzy Logic control). Its’ venting and installation must be checked to keep it running safely and efficiently. REMOVING THE FRONT DOOR...
5. Replace the door carefully to avoid dislodging the gasket. BATTERY BACK UP REPLACEMENT Your YUNCA GAS LEEDZ (Fuzzy Logic control) will operate (WITHOUT FAN BOOST) if power is not available for any reason. Two “D” size batteries are located on the right side plinth panel. Unclip the cover from the top, (it is hinged at the base), and remove the batteries, replacing with fresh ones.
There must be no blockages and the flue must be in good repair. Any sections that are taken apart for inspection must be reassembled and sealed as required. FIG 5: GAS CONTROL VALVE CONNECTIONS Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010 Page 13 of 19...
4. Disconnect earth wire from control valve bracket. 5. Unplug white connector block. 6. Slacken the four screws that attach the fan mounting bracket to the base. 7. Remove fan. Revised 04-08-10 YUNCA Leedz FS Fuzzy Feb 2010 Page 14 of 19...
TROUBLESHOOTING GUIDE –YUNCA FUZZY LOGIC CONTROL SYSTEM P1/2 PROBLEM POSSIBLE CAUSE SOLUTION AC Power IS unplugged or loose, or the fuse has a short Reset the Power Plug or replace the Fuse. (fuse box is located below “AC in”, and slides out, spare fuse within) A.
TROUBLESHOOTING GUIDE–YUNCA FUZZY LOGIC CONTROL SYSTEM continued P2/2 PROBLEM POSSIBLE CAUSE SOLUTION The cables of Flame Sensor and Spark Igniter are Re-arrange or tighten. reversed or loosened. D. Pilot is alight, sparking Flame Sensor doesn't sense the flame. Re-adjust to a suitable position to be burnt by the flame. continues and doesn't stop.
APPENDIX A PARTS LIST – LEEDZ FS (FuzzyLogic): PART NO. PART NAME 6601 Rear Burner - SIT 6699L Front Burner – Furi 316 6602A Pilot assembly 6598RF Flame rod lead (LFS / Fuzion) 6598SF Electrode lead (LFS / FUZiON) 6680*...
APPENDIX C WARRANTY Components of the Yunca Leedz Free Standing Gas Heater are warranted for a period of one year from date of purchase. This includes all gas and electrical components including control, burners, pilot assembly, tubing, fan and switches.
CUSTOMER COPY (complete and retain this section for your records) YUNCA LEEDZ (Fuzzy Logic control) WARRANTY REGISTRATION: Serial No: Gas Type: Purchase Date: Purchasers' Name: Purchasers’ Address: City: PostCode: Telephone: Where Purchased: Installed By: Date: Designed and Manufactured by Yunca Gas Dunedin...