FUZZY LOGIC control AUGUST 2007 INSTALLATION, OPERATION, MAINTENANCE & WARRANTY INFORMATION These instructions should be stored in a convenient safe place for ready reference. Yunca entis instal Aug07 Page 1 of 23 Revised 22-08-07...
(without the fan boost). Ref page 12. The installation of the YUNCA entis FLUED GAS HEATER must be carried out by a suitably qualified person and comply with the current New Zealand installation code, NZS 5261:2003/AG 601:2002.
CONNECTING THE HEATER TO A GAS SUPPLY Burn ONLY the fuel for which the heater is equipped. The YUNCA entis (Fuzzy Logic control) is shipped from the factory equipped to burn either Natural Gas or L.P.G. The Yunca entis (Fuzzy Logic control) Heater cannot be converted from LPG to NG, or vice versa.
ENTIS FASCIA REMOVAL AND APPLICATION Push fascia upwards, this lifts the locating pins clear of the locating holes Pull the fascia forward and remove Reverse this sequence to reapply the fascia GLASS DOOR REMOVAL When fitting the door, put the wing nuts on in a sequence of opposite corners.
Disconnect the main power plug Lift the flap and disconnect the quick connection Location of the automatic fan thermo switch Location of fan switch Slide the fan box out Replace in reverse order Yunca entis instal Aug07 Page 6 of 23 Revised 22-08-07...
Width (mm) Depth (mm) Centre flue to front (mm) Fascia backing frame Fascia front Air vent and access to battery back up, fan box, manual control box/panel, seismic restraint holes. Yunca entis instal Aug07 Page 7 of 23 Revised 22-08-07...
CLEARANCES If a mantel is sought, the minimum clearances shown are required. NOTE: a hearth is not required for this fireplace. Yunca entis instal Aug07 Page 8 of 23 Revised 22-08-07...
TYPICAL ZERO CLEARANCE FLUE INSTALLATION N.B. For frame out and cladding information, refer following page. Yunca entis instal Aug07 Page 10 of 23 Revised 22-08-07...
The AUTO light will flash (when the fire is off) as a reminder that the timer has been activated. BATTERY BACK UP - REPLACEMENT Your YUNCA entis will operate for up to 200 hours (WITHOUT FAN BOOST) if power is not available. Two “D” size batteries are located behind the fascia on the bottom left side, next to the fan box.
INFRA-RED REMOTE CONTROL with AUTO TIMER. POWER ON/OFF: First check that the two AAA batteries are inserted. The remote may appear to be on, but it is likely that is not so. To turn on the remote control (it is protected with a “kiddy lock”), press and hold the POWER button for about 2 seconds until “off”...
Page 14
You are effectively temporarily overriding the automatic control, e.g. if you wish to stop the fire running at an earlier time. Yunca entis instal Aug07 Page 14 of 23 Revised 22-08-07...
Page 15
ENTIS REMOTE CONTROL DISPLAY ICONS N.B.- DO NOT LEAVE THE REMOTE CONTROL ON TOP OF YOUR FIRE FASCIA! Yunca entis instal Aug07 Page 15 of 23 Revised 22-08-07...
A qualified service person should conduct an annual inspection and undertake any maintenance required on your entis heater. The venting and installation must be checked to keep it running safely and efficiently. The gas supply and electrical power should be isolated whenever any maintenance procedures are undertaken.
Glass 1611EE Glass thermotape seal 1955 Rocker switch Fascia front (State Colour) Fascia backing frame (State Colour) 8950Fz Main door (State Colour) Combustion Plate Remote control hand piece (Fuzzy Logic) Yunca entis instal Aug07 Page 17 of 23 Revised 22-08-07...
TECHNICAL INFORMATION APPENDIX A INJECTOR SIZE: GAS TYPE FRONT BURNER BACK BURNER NATURAL 2.3mm diameter 2.3mm diameter L.P.G. (NZ ONLY) 1.15mm diameter 1.15mm diameter FAN WIRING DIAGRAM Yunca entis instal Aug07 Page 18 of 23 Revised 22-08-07...
GAS CONTROL VALVE CONNECTIONS HEAT CELL (ZERO CLEARANCE KIT) ASSEMBLY Purchased separately (Part number 6699EN). Supplied in a “flat pack”. Use the screws supplied to assemble in the order shown below. Yunca entis instal Aug07 Page 19 of 23 Revised 22-08-07...
TROUBLESHOOTING GUIDE –YUNCA FUZZY LOGIC CONTROL SYSTEM P1/2 PROBLEM POSSIBLE CAUSE SOLUTION AC Power IS unplugged or loose, or the fuse has a short Reset the Power Plug or replace the Fuse. (fuse box is located below “AC in”, and slides out, spare fuse within) A.
Page 21
TROUBLESHOOTING GUIDE–YUNCA FUZZY LOGIC CONTROL SYSTEM continued P2/2 PROBLEM POSSIBLE CAUSE SOLUTION The cables of Flame Sensor and Spark Igniter are Re-arrange or tighten. reversed or loosened. D. Pilot is alight, sparking Flame Sensor doesn't sense the flame. Re-adjust to a suitable position to be burnt by the flame. continues and doesn't stop.
APPENDIX D Warranty Components of the Yunca entis inbuilt gas heater are warranted for a period of one year from date of purchase. This includes all gas and electrical components including control, burners, pilot assembly, tubing, fan and switches. Glass and surface coatings are also warranted for one year.
APPENDIX E CUSTOMER COPY (complete and retain this section for your records) YUNCA entis WARRANTY REGISTRATION: Serial No. Gas Type. Purchase Date Purchasers' Name. Purchasers’ Address. City. Postcode. Telephone Where Purchased. Installed By. Date. Designed and Manufactured by Yunca Gas Dunedin...