CLEANING THE FILTER
This is the one maintenance procedure designed to be carried out by the householder. The filter
should be cleaned periodically to maintain an unrestricted air passage to the fan.
The filter is found at the back of the fire (see below). To clean, use a vacuum cleaner or similar
to remove any dust or lint build up. The filter is not designed to be removed for general
cleaning.
The area behind the fire should be maintained in a clean state. This reduces the possibility of the
fan picking foreign matter that will cause fan noise or damage.
HOW TO REMOVE FAN
Fan removal for cleaning.
1. IMPORTANT. Unplug the fan from the power supply.
2. Remove the front plinth by pulling clear of the locating pins.
3. Undo the screws attaching the switch block inside the heater
4. Loosen the four screws holding the Fan Back to the plinth at the back of the heater. Screws
should be loosened but do not need to be removed.
5. The Fan Back that contains the fan is removed from the back of the fire by lifting up off the
screws.
6. The fan blades can be cleaned of any dirt and grim.
7. Reassemble
The fan assembly should only be disassembled by an electrician or trained Yunca Technician.
25-07-01
Page 15 of 23
Operation Instructions for Eros Free Standing Gas Fire July 2001.doc