Yunca Gas EROS User Manual page 14

Flued
Table of Contents

Advertisement

10. Replace and relatch the front door, replace the side panels and top.
CLEANING THE TOP AND LOUVRES
Note: If a flue guard kit has been fitted this may need to be removed. This is done by sliding the
front half up and out and unscrewing the back half from its brackets.
The top panel is held in place by four retaining pins. The top panel must be removed, to do this
grip panel at the front edge and the back corner. Pulling up will disengage the locating pin. Then
working the hand position around the panel to disengage all the locating pins.
Care needs to be taken not to damage any panels by keeping the panels from touching each other
during this process.
Slide the top panel up the flue until there is sufficient space to vacuum any dust and lint that may
be lying under the panel.
This is also a good time to wipe the front louvers with a soft cloth.
CLEANING THE (OPTIONAL) GOLD DOOR/PARTS
The gold finish is very soft. Care must be taken not to damage the gold coating.
Cleaning must be completed using a soft non-abrasive damp cloth.
NEVER use an ABRASIVE on the gold finish. The gold coating can easily be removed with
the lightest rub with abrasive material.
INSPECTING THE VENTING
An inspection of the venting system should be made during the annual service appointment.
There must be no blockages and the flue must be in good repair. Any sections that are taken apart
for inspection must be reassembled and sealed as required.