MAINTENANCE

A qualified service person recommended by your YUNCA dealer should conduct an annual inspection
and undertake any maintenance required on your JERVOIS. Its venting and installation must be
checked to keep it running safely and efficiently. The following procedures should be performed only
by a qualified service person. The gas supply and electrical power should be isolated whenever any
maintenance procedures are undertaken.
Note: the door can only be removed after the heater has been turned off for long enough so that the
door has cooled to touching temperature.
Removing The Front Door
1. Remove the two rods that form the grill above the door. Sliding a rod to the left, allowing the right
hand end to be disengaged from the side panel. Moving the end clear and extracting the rod out
of the left hand side panel and clear. Repeat for the second rod.
2. This will expose the restraining thumb screws at each side of the door. To open, unscrew the two
thumb screws.
3. The front door can now be removed by pulling the door forward at the top with a slight lift.
4. Lift the door clear of the retaining lip at the bottom of the door.
Replacing the door is the reverse operation. Take care the glass seal is maintained in its correct
position and the thumb screws are tightened to achieve an effective seal
Removing The Glass For Replacement.
1. Remove the front door as described above, and place front down on a soft surface.
2. Remove the screws around the perimeter of the inner door and lift clear.
3. The glass can be lifted clear and discarded or the seal removed. The imitation lead light insert is
loose in the door front.
4. New glass with gasket attached can be ordered through your YUNCA agent.
Note: Only recommended heat resistant glass may be fitted.
5. Place replacement glass in position in the reverse order of removal. Ensure the imitation lead light
insert is centralised before tightening of the screws
Note: Tighten the screws alternately, do not over tighten to avoid damaging glass.
Screws and spire clips may need replacement is suitable assembly compression is not achieved
19-07-05
Page 11 of 20
Operation Instructions for Jervois Freestanding Gas Heater March 2002