Last Fault; Sensor Temperature Conversion - Fisher & Paykel RB90S64MKIW Service Manual

Refrigerated drawer
Table of Contents

Advertisement

rd
• The 3
LED from the left indicates that the condenser fan is on.
nd
• The 2
LED from the right indicates that the auxiliary heater is on.
• The right hand LED indicates that the defrost heater is on.
6.
To return to normal operation, press and hold the LOCK button, then within 1 second press the
FUNCTION SELECT button. Hold for 3 seconds.
10.1.4.9

Last Fault

Flashing
1
To read the Last Fault:
1.
Open the drawer.
2.
Press the LOCK button for 3 seconds to unlock the control panel.
3.
Within 15 seconds, press and hold the LOCK button, then within 1 second press the FUNCTION
SELECT button. Hold for 3 seconds.
4.
Press the WARMER button eight times.
5.
The Pantry LED will be illuminated.
temperature indicator LEDs (refer to Section 10.1.1).
6.
To return to normal operation, press and hold the LOCK button, then within 1 second press the
FUNCTION SELECT button. Hold for 3 seconds.
Note: The last fault is cleared from the memory after the next defrost.
10.1.5

Sensor Temperature Conversion

If the red Freezer LED plus one other LED is on (refer to Section 10.1.4), this indicates that a sensor
temperature is being displayed. Temperatures are read as follows:
Each temperature scale LED has a numerical value. The values from left to right are: 32, 16, 8, 4, 2, 1 and
0.5. If the LOCK LED is off, it is a positive temperature, and if the LOCK LED is on, it is a negative
temperature.
To obtain the temperature of any of the sensors:
1.
Obtain the binary code of the sensor reading (refer to Sections 10.1.4 to 10.1.4.6).
2.
Add up the binary number indicated by the temperature indicator LED pattern (see Figure above).
The Last Fault is displayed in a Binary code form in the
32
16
Temperature Binary Code
47
8
4
2
1
0.5