Defrost Cycle

The following table outlines the defrost cycle of the CoolDrawer.
Note: The defrost interval (time between defrosts) is calculated using compressor percentage run time, the number of drawer openings and the duration of the last
defrost.
O
O
If the defrost sensor fails to reach +8
C (46
F) within 40 minutes, the defrost will be terminated. If this occurs again during the next defrost, fault code 2 will be
displayed.
Compressor
Defrost Element
Defrost target time 24 minutes
Defrost Element
Compressor
Compartment Fan
Turns Off
Turns On
Maximum defrost time is 40 minutes
Turns Off
Turns On
Turns On
Normal Run
Warm up Time
Defrost Time
Drip Time
Normal Run
5 Minutes
(Target time 24 minutes)
3 minutes
7 minutes