Removal Of Humidity Lid Control; Removal Of Evaporator Fan Motor - Fisher & Paykel RB90S64MKIW Service Manual

Refrigerated drawer
Table of Contents

Advertisement

12.3.25

Removal Of Humidity Lid Control

• To unclip the controls, insert a small
screwdriver into the holes under the control
and push upwards on both tabs. Slide the
control inwards.
Refit in reverse order.
12.3.26

Removal Of Evaporator Fan Motor

• Gain access to the evaporator area (refer to
Section 12.3.17).
• Using two fingers, withdraw the fan housing
outwards at the top, and then upward.
• Remove the air bell cover by lifting upwards.
• Remove the fan wiring plug from the air bell
socket.
• The fan motor housing can be split in half by
prising the two clips on the top outwards and
spreading the housing apart.
Refit in reverse order.
Note: The fan is supported in the housing by a
rubber band type suspension. It is important that
the fan sits central to the housing and that there
is a loop in the fan motor wiring harness between the motor and the housing wiring post. This loop should
be on a horizontal plane to the fan motor. Failure to correctly fit the fan will result in fatigue failure of the
wiring harness and also in noisy operation. Ensure that the fan wiring does not prevent the fan blade from
rotating.
To refit the housing, first fit the wiring harness multi plug into the pocket of the divider partition. The fan
motor housing needs to be locked together to enable it to be refitted.
Front view of the evaporator fan in its housing
Rear view of the evaporator fan with the rear
housing removed
69