Removal Of Condenser Fan; Removal Of Power/Control Module; To Gain Access To Evaporator Area - Fisher & Paykel RB90S64MKIW Service Manual

Refrigerated drawer
Table of Contents

Advertisement

12.3.15

Removal Of Condenser Fan

Located
to
the
right
power/control module.
• Remove the front chassis cover (refer to
Section 12.3.6).
• Remove the polystyrene moulding from the
front of the fan.
• Unplug the fan motor connection harness
located in the pocket alongside the fan motor.
• Depress the 2 clips on either side of the fan
motor housing to enable it to be withdrawn
forward and removed.
Refit in reverse order.
Note: When installed, the fan hub should face the installer. The polystyrene block must not obstruct the fan
blade.
12.3.16

Removal Of Power/Control Module

Located in the centre front of the drawer.
• Remove the front chassis cover (refer to
Section 12.3.6).
• Depress the clip on the top edge of the
power/control module and pull the module
forwards slightly.
• Remove the three edge connectors from the
front of the module.
• Slide the module further forward and remove
the three edge connectors from the side of
the module.
• The module can now be removed completely.
Refit in reverse order.
12.3.17

To Gain Access To Evaporator Area

• Remove the drawer front panel (refer to
Section 12.3.8).
• With a small screwdriver, prise the two lugs
securing the front of the evaporator cover
backwards. This allows the front of the cover
to be lifted, then moved forwards and clear.
Refit in reverse order.