840653
10.1.4.6
Filter Sensor Temperature
Flashing
1
To read the Filter Sensor Temperature:
1.
Open the drawer.
2.
Press the LOCK button for 3 seconds to unlock the control panel.
3.
Within 15 seconds, press and hold the LOCK button, then within 1 second press the FUNCTION
SELECT button. Hold for 3 seconds.
3.
Press the WARMER button five times.
4.
The Freezer and Fast Freeze LEDs will be illuminated. The current Filter Sensor temperature is
displayed in a Binary code form in the temperature indicator LEDs.
5.
To return to normal operation, press and hold the LOCK button, then within 1 second press the
FUNCTION SELECT button. Hold for 3 seconds.
10.1.4.7
Input Status
Flashing
1
To read the Input Status:
1.
Open the drawer.
2.
Press the LOCK button for 3 seconds to unlock the control panel.
3.
Within 15 seconds, press and hold the LOCK button, then within 1 second press the FUNCTION
SELECT button. Hold for 3 seconds.
4.
Press the WARMER button six times.
5.
The Chill LED will be illuminated.
temperature indicator LEDs. The Input Status only uses the second LED from the right on the
temperature scale. If the LED is on it indicates that the drawer is closed, while if it is off it indicates
that the drawer is open. This status can be used to check that the reed switch is operating correctly.
6.
To return to normal operation, press and hold the LOCK button, then within 1 second press the
FUNCTION SELECT button. Hold for 3 seconds.
10.1.4.8
Output Status
Flashing
1
To read the Output Status
1.
Open the drawer.
2.
Press the LOCK button for 3 seconds to unlock the control panel.
3.
Within 15 seconds, press and hold the LOCK button, then within 1 second press the FUNCTION
SELECT button. Hold for 3 seconds.
4.
Press the WARMER button seven times.
5.
The Fridge LED will be illuminated. The current Output Status is displayed in a code form in the
temperature indicator LEDs.
• The left hand LED indicates that the compressor is on.
nd
• The 2
LED from the left indicates that the evaporator fan is on.
The current Input Status is displayed in a code form in the
46
2
2
2