Checking and solving nozzle clogging

Make test printing to check whether there is nozzle clogging or other printing failures.
If the finished test pattern shows any sign of abnormal conditions, carry out the cleaning
function.

Normal pattern

Print the test pattern
• If the temperature in the water heater or in the UV device has not reached
the predetermined value, a message is indicated. In this case, printing is
disabled. It is enabled when the error indication has disappeared.
STEPS:
Make sure to set the media and the origin.
1. Make sure that Local mode is displayed.
2. Press the [TEST] key.
Gap check is performed when the head gap
adjustment has not been checked. (
3. Press the [ENTER] key.
The device prints the test pattern.
4. After the printing test pattern, the table
moves towards, and then the device
enters the LOCAL mode.
5. Check the test patterns.
If a failure occurs, proceed with step next; other-
wise, terminate the operation.
Black(K)
Cyan(C)
***********
UV NOT READY
Light
Cyan(Lc)
Magenta(M)
Yellow(Y)
************
WATER NOT READY
P.2-13)
- 2-19 -
Light
Magenta(Lm)
White(W)
<< LOCAL >>
TEST DRAW
NOZZLE CHECK
< ENT >
** TEST DRAW **
<< LOCAL >>

Advertisement